View Categories

Update not installed or web interface not updated

Free Pro

MikroWizard checks for updates every hour and when it starts. Backend (MikroMan) and web interface (MikroFront) are updated separately; both versions are on the dashboard Version & License card.

No update is offered #

  1. Licence username: without a License Username, MikroWizard doesn’t check for updates. See Licence and registration messages.
  2. Internet access: the server must reach mikrowizard.com. If the dashboard shows Connection Error, fix the server’s connection first.
  3. Update mode: in Manual mode, updates are shown but not installed. Click Update next to Mikroman Backend (or the web interface) on the dashboard and confirm. See Update modes.

The update stays pending #

Restart the backend to start a check now:

sudo docker restart mikroman

Then follow the log:

sudo docker logs --tail 100 -f mikroman

Lines from the update checker show whether an update was found, downloaded and verified. A checksum mismatch means the download was damaged; MikroWizard deletes it and tries again at the next check.

The web interface doesn’t update #

If the dashboard shows ACTION REQUIRED — the MikroFront auto-updater has stopped, run the command shown in the message once on the server:

sudo sh -c 'docker exec mikrofront rm -f /etc/cron.d/mwcrontab; touch /opt/mikrowizard/nginx-ssl-redirect.conf /opt/mikrowizard/nginx-ssl-server.conf; docker restart mikrofront'

MikroWizard shows this message when the web interface hasn’t checked for updates for more than 90 minutes.

Next step #